pH, DO, OD and CO₂: What each parameter measures in a cell culture

pH, DO, OD and CO₂: Key cell culture parameters and what they measure

In any laboratory or biopharmaceutical plant working with cell cultures, controlling the cell culture parameters is essential. Cells, whether microbial, mammalian, or insect, require very specific conditions to grow and produce properly. This is where four key parameters come into play: pH, DO, OD, and CO₂.

Although these are common acronyms in bioprocesses, their exact meanings, what they measure, and why they matter as cell culture parameters are not always clear. In this blog, we clearly and rigorously explain each one, their relationship with cell physiology, and their impact on biotechnological process productivity.

pH: Acid-Base Balance of the Medium

pH indicates the acidity or alkalinity of the culture medium. As one of the most critical cell culture parameters, pH directly affects protein stability, enzymatic activity, nutrient availability, and membrane integrity. Cells are very sensitive to pH changes, making its control essential for optimal growth.

  • Optimal value: usually ranges from 6.8 to 7.4 for mammalian cells, although other species may require different conditions.
  • Too acidic: can damage cells, affect gene expression, and induce metabolic stress.
  • Too alkaline: can disrupt ionic gradients and the absorption of certain compounds.

pH is measured in real time using chemical or non-invasive optical sensors, and is automatically controlled by adjusting the addition of gases (like CO₂), bases (like NaOH), or acids (like HCl), ensuring a stable physiological environment.

DO: Dissolved Oxygen

DO represents the amount of dissolved oxygen in the culture medium, expressed as a percentage of saturation or in mg/L. As one of the most important cell culture parameters, it is critical in aerobic cultures such as animal cells, recombinant cell lines, or bacteria like E. coli.

  • Ideal value: between 30% and 80% saturation, depending on the cell type and process goal.
  • Low DO: cells cannot obtain enough oxygen to produce energy (ATP) via respiration, limiting proliferation and productivity.
  • High DO: can generate reactive oxygen species (ROS), leading to oxidative damage.

Dissolved oxygen sensors, often based on optical technology, enable precise control of aeration, oxygen supply, and agitation speed, maintaining adequate levels throughout the culture phases.

OD: Optical Density or Turbidity

OD, or optical density, is an indirect measure of cell concentration in the medium. As one of the key cell culture parameters, it relies on the cells’ ability to absorb or scatter light emitted at a specific wavelength. It’s one of the fastest and simplest ways to estimate cell growth.

  • OD600: most commonly used wavelength for bacterial cultures.
  • OD420-450: more commonly used for yeasts and other microorganisms.
  • Higher OD = more biomass, although it can saturate in very dense cultures.

While OD does not distinguish between live and dead cells, it is useful for plotting growth curves, identifying culture phases (lag, log, stationary), and optimizing harvest times. It can be measured with spectrophotometers or inline sensors connected to the bioreactor.

CO₂: Atmospheric Control and pH Regulation

CO₂ (carbon dioxide) plays key roles as one of the essential cell culture parameters:

  • Regulates pH: when dissolved in the medium, it forms carbonic acid (H₂CO₃), which lowers pH.
  • Maintains culture homeostasis: many mammalian-derived cells are adapted to 5%-10% CO₂ environments, similar to intracellular and human body conditions.

CO₂ control is achieved by automatically adjusting the gas mixture (air, oxygen, nitrogen, CO₂) introduced into the system. Sensors measure CO₂ concentration and allow real-time stabilization, especially in incubators and bioreactors.

Interaction between parameters: An interconnected ecosystem

These parameters do not act in isolation. They are closely interrelated:

  • CO₂ regulates pH but also affects cellular metabolism.
  • Aeration influences both DO and medium evaporation, indirectly altering pH.
  • pH affects enzymatic activity, which in turn impacts oxygen demand and CO₂ production.

That’s why modern culture and fermentation systems integrate automated platforms with inline sensors and advanced control systems. This allows precise and dynamic regulation of each cell culture parameter to maintain the necessary balance for successful cultivation.

TECNIC technology for total control

At TECNIC, we develop advanced solutions for the precise control of key cell culture parameters. Our laboratory, pilot plant, and production bioreactors are equipped with:

  • High-precision sensors for pH, DO, CO₂, and OD
  • Data acquisition systems and automatic control
  • Intuitive software to customize alarms, scale-up, and data logging
  • Compatibility with single-use or multi-use technologies

Whether in R&D contexts, recombinant protein manufacturing, vaccine production, or cell therapy, maintaining stable cell culture parameters ensures quality, safety, and efficiency throughout the biotechnological process.

Tips to improve monitoring and control in cell culture

  • Calibrate sensors regularly: especially pH and DO sensors, to maintain accurate readings.
  • Verify medium homogeneity: poorly mixed areas may show unrepresentative pH or DO values.
  • Continuous monitoring: real-time data collection enables proactive adjustments and prevents failures.
  • Integrate automated alarms: to detect critical deviations before compromising the culture.
  • Validate the entire system under real operating conditions.

Conclusion

Controlling cell culture parameters such as pH, DO, OD, and CO₂ is more than a technical detail, it's the foundation of any biotechnological strategy. The stability of these parameters ensures robust, productive, and reproducible cell cultures.

Thanks to the development of advanced sensors, automated systems, and intelligent software, companies like TECNIC empower laboratories and biopharmaceutical plants to operate with maximum reliability.

The biotechnology of the future is built on data, precision, and control. And it all starts with understanding and mastering these four pillars of cell culture.

FAQ: pH, DO, OD and CO₂ in Cell Culture

Frequently Asked Questions (FAQ)

1. What is pH?

It shows how acidic or basic the liquid is.

2. What is DO?

It means how much oxygen is in the liquid.

3. What is OD?

It tells how many cells are growing, by measuring how cloudy the liquid is.

4. What is CO₂ used for?

It helps keep the pH level right and supports cell growth.

5. Why are these parameters important?

They help cells grow well and produce what we need.

6. How are these parameters controlled?

With sensors and machines that adjust things like air, gases, and liquids.

7. What does pH measure in a cell culture?

It measures the acidity or alkalinity of the medium, crucial for enzyme activity and cell health.

8. Why is dissolved oxygen (DO) important?

Cells need oxygen for energy. Low DO reduces productivity; high DO can cause oxidative stress.

9. What does OD indicate?

OD estimates cell concentration by measuring how much light is absorbed or scattered.

10. How does CO₂ affect cell cultures?

It helps regulate pH and simulates mammalian growth conditions (usually 5–10% CO₂).

11. Do these parameters affect each other?

Yes. For example, CO₂ alters pH, and oxygen levels impact metabolism and CO₂ production.

Subscribe to our newsletter

Newsletter Form

Contact form

Your opinion is very important to us, and we encourage you to contact our sales team to discuss the purchase of our bioprocess equipment. We are here to answer your questions and help you find the best solution for your needs.

Quote
Related Content

Quote

Quote

Coming soon 

We are finalizing the details of our new equipment. Soon, we will announce all the updates. If you want to receive all the latest news about our products, subscribe to our newsletter or follow our social media channels. 

Newsletter Form

Sign Up

Stay informed about our product innovations, best practices, exciting events and much more! After signing up for our newsletter, you can unsubscribe at any time.

Newsletter Form

Rushton impeller

The Rushton impeller, also known as the flat disk impeller. It emerged as a solution to the challenges of mixing and oxygenation in the biotechnology industry. Its innovative design was quickly recognized for its exceptional ability to generate turbulent flow, making it a standard in the sector for decades.

Pitch blade impeller

This component is crucial for optimizing mixing and mass transfer in cell culture processes. Its specific design facilitates homogeneous distribution of nutrients and gases, essential for maintaining cell viability and growth under optimal conditions.

Rushton impeller

Characterized by its radial blades mounted perpendicularly to the shaft, the Rushton impeller is engineered to provide high shear rates and excellent gas dispersion, which is particularly effective in microbial. In biotechnological applications involving bacteria and yeast, the Rushton impeller excels by ensuring homogeneous mixing and optimal gas distribution, even in high-density cultures.

Cassette

We understand the importance of flexibility and efficiency in laboratory processes. That's why our equipment is designed to be compatible with Cassette filters, an advanced solution for a variety of filtration applications. Although we do not manufacture the filters directly, our systems are optimized to take full advantage of the benefits that Cassette filters offer.

Cassette filters are known for their high filtration capacity and efficiency in separation, making them ideal for ultrafiltration, microfiltration, and nanofiltration applications. By integrating these filters into our equipment, we facilitate faster and more effective processes, ensuring high-quality results.

Our equipment, being compatible with Cassette filters, offers greater versatility and adaptability. This means you can choose the filter that best suits your specific needs, ensuring that each experiment or production process is carried out with maximum efficiency and precision.

Moreover, our equipment stands out for its 100% automation capabilities. Utilizing advanced proportional valves, we ensure precise control over differential pressure, transmembrane pressure, and flow rate. This automation not only enhances the efficiency and accuracy of the filtration process but also significantly reduces manual intervention, making our systems highly reliable and user-friendly.

Hollow Fiber

We recognize the crucial role of flexibility and efficiency in laboratory processes. That's why our equipment is meticulously designed to be compatible with Hollow Fiber filters, providing an advanced solution for a broad spectrum of filtration applications. While we don't directly manufacture these filters, our systems are finely tuned to harness the full potential of Hollow Fiber filters.

Hollow Fiber filters are renowned for their exceptional performance in terms of filtration efficiency and capacity. They are particularly effective for applications requiring gentle handling of samples, such as in cell culture and sensitive biomolecular processes. By integrating these filters with our equipment, we enable more efficient, faster, and higher-quality filtration processes.

What sets our equipment apart is its 100% automation capability. Through the use of sophisticated proportional valves, our systems achieve meticulous control over differential pressure, transmembrane pressure, and flow rate. This level of automation not only boosts the efficiency and precision of the filtration process but also significantly diminishes the need for manual oversight, rendering our systems exceptionally reliable and user-friendly.

Contact General

Discover our Clean Room

How are our single-use bags manufactured?

Tangential Flow Filtration Solutions

Single-Use Bioreactors

Europe
America
India
Middle East
Asia - Pacific

Contact General